Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Adicionar filtros








Intervalo de ano
1.
Tissue Engineering and Regenerative Medicine ; (6): 421-432, 2017.
Artigo em Inglês | WPRIM | ID: wpr-655767

RESUMO

Mesenchymal stem cells (MSCs), which are multipotent and have self-renewal ability, support the regeneration of damaged normal tissue. A number of external stimuli promote migration of MSCs into peripheral blood and support their participation inwound healing. In an attempt to harness the potential beneficial effects of such external stimuli, we exposed human MSCs (hMSCs) to one such stimulus-low-dose ionizing radiation (LDIR)-and examined their biological properties. To this end, we evaluated differences in proliferation, cell cycle, DNA damage, expression of surface markers (CD29, CD34, CD90, and CD105), and differentiation potential ofhMSCs before and after irradiation with γ-rays generated using a ¹³⁷ CSirradiator.At doses less than 50 mGy, LDIR had no significant effect on the viability or apoptosis of hMSCs. Interestingly, 10 mGyofLDIR increased hMSC viability by 8% (p<0.001) comparedwith non-irradiatedhMSCs.At doses less than 50 mGy, LDIR did not induceDNA damage, including DNA strand breaks, or cause cellular senescence or cell-cycle arrest. Surface marker expression and in vitro differentiation potential of hMSCs were maintained after two exposures to LDIR at 10 mGy per dose. In conclusion, a two-dose exposure to LDIR at 10 mGy per dose not only facilitates proliferation of hMSCs, it alsomaintains the stem cell characteristics of hMSCswithout affecting their viability.These results provide evidence for the potential ofLDIRas an external stimulus for in vitro expansion of hMSCs and application in tissue engineering and regenerative medicine.


Assuntos
Humanos , Apoptose , Senescência Celular , Proliferação de Células , DNA , Dano ao DNA , Técnicas In Vitro , Células-Tronco Mesenquimais , Radiação Ionizante , Regeneração , Medicina Regenerativa , Células-Tronco , Engenharia Tecidual
2.
Korean Journal of Medical Physics ; : 140-147, 2011.
Artigo em Coreano | WPRIM | ID: wpr-99719

RESUMO

The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was 1.59x2.50 mm. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.


Assuntos
Animais , Pulmão , Veias
3.
Korean Journal of Medical Physics ; : 198-205, 2011.
Artigo em Coreano | WPRIM | ID: wpr-153493

RESUMO

Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates 360degrees during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.


Assuntos
Experimentação Animal , Alemanha , Vidro
4.
Korean Journal of Medical Physics ; : 206-215, 2011.
Artigo em Coreano | WPRIM | ID: wpr-153492

RESUMO

The purpose of this was to investigate the measurement of fluence dose map for the specific patient quality assurance. The measurement of fluence map was performed using 2D matrixx detector. The absorbed dose was measured by a glass detector, Gafchromic film and ion chamber in Hybrid Optimized VMAT Phantom (HOVP). For 2D Matrixx, the results of comparison were average passing rate 85.22%+/-1.7 (RT_Target), 89.96%+/-2.15 (LT_Target) and 95.14%+/-1.18 (G4). The dose difference was 11.72%+/-0.531, -11.47%+/-0.991, 7.81%+/-0.857, -4.14%+/-0.761 at the G1, G2, G3, G4. In HOVP, the results of comparison for film were average passing rate (3%, 3 mm) 93.64%+/-3.87, 90.82%+/-0.99. We were measured an absolute dose in steep gradient area G1, G2, G3, G4 using the glass detector. The difference between the measurement and calculation are 8.3% (G1), -5.4% (G2), 6.1% (G3), 7.2% (G4). The using an Ion-chamber were an average relative dose error -1.02%+/-0.222 (Rt_target), 0.96%+/-0.294 (Lt_target). Though we need a more study using a transmission detector. However, a measurement of real-time fluence map will be predicting a dose for real-time specific patient quality assurance in volume modulated arc therapy.


Assuntos
Humanos , Quimera , Vidro
5.
Korean Journal of Medical Physics ; : 216-223, 2011.
Artigo em Coreano | WPRIM | ID: wpr-153491

RESUMO

Recently PTW developed a MicroLion liquid ionization chamber which is water_equivalent and has a small sensitive volume of 0.002 cm3. The aim of this work is to investigate such dosimetric characteristics as dose linearity, dose rate dependency, spatial resolution, and output factors of the chamber for the external radiotherapy photon beam. The results were compared to those of Semiflex chamber, Pinpoint chamber and Diode chamber with the sensitive volumes of 0.125 cm3, 0.03 cm3 and 0.0025 cm3, respectively and evaluated to be suitable for small fields. This study was performed in the 6MV photon energy from a Varian 2300 C/D linac accelerator and the MP3 water phantom (PTW, Freiburg) was used. Penumbras in the varios field sizes ranged from 0.5x0.5 cm2 to 10x10 cm2 were used to evaluate the spatial resolution. Output factors were measured in the field sizes of 0.5x0.5 to 40x40 cm2. Readings of the chamber was linearly proportional to dose. Dose rate dependency was measured from 100 MU/min to 600 MU/min, showed a maximum difference of 5.0%, and outputs decreased with dose rates. The spatial resolutions determined with comparing profiles for the field sizes of 0.5x0.5 cm2 to 10x10 cm2 agreed between every detector except the Semiflex chamber to within 2%. Outputs of detectors were compared to that of Semiflex chamber and showed good agreements within 2% for every chamber. This study shows that MicroLion chamber characterized by a high signal-to-noise ratio and water equivalence could be suitable for the small field dosimetry.


Assuntos
Dependência Psicológica , Leitura , Razão Sinal-Ruído , Análise Espacial , Água
6.
Korean Journal of Medical Physics ; : 3-11, 2011.
Artigo em Coreano | WPRIM | ID: wpr-124378

RESUMO

The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.


Assuntos
Vértebra Cervical Áxis , Estudos de Viabilidade , Vidro
7.
Korean Journal of Medical Physics ; : 42-51, 2011.
Artigo em Coreano | WPRIM | ID: wpr-124373

RESUMO

Nuclear medicine images (SPECT, PET) were widely used tool for assessment of myocardial viability and perfusion. However it had difficult to define accurate myocardial infarct region. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using polar map with adaptive threshold. Rat myocardial infarction model was induced by ligation of the left circumflex artery. PET images were obtained after intravenous injection of 37 MBq 18F-FDG. After 60 min uptake, each animal was scanned for 20 min with ECG gating. PET data were reconstructed using ordered subset expectation maximization (OSEM) 2D. To automatically make the myocardial contour and generate polar map, we used QGS software (Cedars-Sinai Medical Center). The reference infarct size was defined by infarction area percentage of the total left myocardium using TTC staining. We used three threshold methods (predefined threshold, Otsu and Multi Gaussian mixture model; MGMM). Predefined threshold method was commonly used in other studies. We applied threshold value form 10% to 90% in step of 10%. Otsu algorithm calculated threshold with the maximum between class variance. MGMM method estimated the distribution of image intensity using multiple Gaussian mixture models (MGMM2, em leader MGMM5) and calculated adaptive threshold. The infarct size in polar map was calculated as the percentage of lower threshold area in polar map from the total polar map area. The measured infarct size using different threshold methods was evaluated by comparison with reference infarct size. The mean difference between with polar map defect size by predefined thresholds (20%, 30%, and 40%) and reference infarct size were 7.04+/-3.44%, 3.87+/-2.09% and 2.15+/-2.07%, respectively. Otsu verse reference infarct size was 3.56+/-4.16%. MGMM methods verse reference infarct size was 2.29+/-1.94%. The predefined threshold (30%) showed the smallest mean difference with reference infarct size. However, MGMM was more accurate than predefined threshold in under 10% reference infarct size case (MGMM: 0.006%, predefined threshold: 0.59%). In this study, we was to evaluate myocardial infarct size in polar map using multiple Gaussian mixture model. MGMM method was provide adaptive threshold in each subject and will be a useful for automatic measurement of infarct size.


Assuntos
Animais , Ratos , Artérias , Eletrocardiografia , Fluordesoxiglucose F18 , Infarto , Injeções Intravenosas , Ligadura , Infarto do Miocárdio , Miocárdio , Medicina Nuclear , Oligossacarídeos , Perfusão
8.
Korean Journal of Medical Physics ; : 52-58, 2011.
Artigo em Inglês | WPRIM | ID: wpr-124372

RESUMO

Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; R2 of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was +/-1.2%. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from 0degrees to 90degrees and GD's maximum response differencewas 14% lower at 180degrees. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within +/-1.5% except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.


Assuntos
Elétrons , Estudos de Viabilidade , Vidro , Aceleradores de Partículas , Água
9.
Korean Journal of Medical Physics ; : 14-20, 2009.
Artigo em Inglês | WPRIM | ID: wpr-88372

RESUMO

We measured the dose distribution for spinal cord and tumor using Gafchromic film, applying 3D and 4D-Treatment Planning for lung tumor within the phantom. A measured dose distribution was compared with a calculated dose distribution generated from 3D radiation treatment planning and 4D radiation treatment planning system. The agreement of the dose distribution in tumor for 3D and 4D treatment planning was 90.6%, 97.64% using gamma index computed for a distance to agreement of 1 mm and a dose difference of 3%. However, a gamma agreement index of 3% dose difference tolerence of and 2 mm distance to agreement, the accordance of the dose distribution around cord for 3D and 4D radiation treatment planning was 57.13%, 90.4%. There are significant differences between a calculated dose and a measured dose for 3D radiation treatment planning, no significant differences for 4D treatment planning. The results provide the effectiveness of the 4D treatment planning as compared to 3D. We suggest that the 4-dimensional treatment planning should be considered in the case where such equipments as Cyberknife with the real time tracking system are used to treat the tumors in the moving organ.


Assuntos
Pulmão , Radiocirurgia , Medula Espinal , Atletismo
10.
Journal of Korean Medical Science ; : 1165-1169, 2009.
Artigo em Inglês | WPRIM | ID: wpr-63995

RESUMO

To understand trends in the clinical characteristics of radiation oncology over the last 10 yr in Korea, annual survey questionnaires were sent to all of Korean radiation oncology facilities since 1990. Questionnaires addressed basic radiation therapy facilities and the clinical information. Responses were obtained from all facilities, and data collected from 1997 to 2006 was analyzed. The numbers of new patients that have undergone radiation therapy and the numbers of hospitals with a department of radiation oncology have steadily increased over the past 10 yr, and totaled 37,215 patients and 60 hospitals, respectively, in 2006. However, the proportion of patients irradiated among total cancer patients has remained below 30% over the last 10 yr. The numbers of prostate cancer, breast cancer, and hepatoma have increased by more than 3 fold over the past 10 yr. Moreover, the percentage of irradiated patients treated by brachytherapy was 10.3% in 1997, but this gradually fell to only 4.2% in 2006. The information collected described the role played by radiation oncology in Korea. Continuous surveys are required to enable trends to be detected.


Assuntos
Feminino , Humanos , Masculino , Braquiterapia/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Coreia (Geográfico)/epidemiologia , Neoplasias/epidemiologia , Inquéritos e Questionários , Radioterapia (Especialidade)/métodos , Sistema de Registros
11.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 166-172, 2008.
Artigo em Coreano | WPRIM | ID: wpr-154636

RESUMO

PURPOSE: The measurement of radiosensitivity of individuals is useful in radiation therapy. Unfortunately, the measurement of radiation survival using a clonogenic assay, which is the established standard, can be difficult and time consuming. The aim of this study is to compare radiosensitivity results obtained from the MTT and clonogenic assays, and to evaluate whether the MTT assay can be used on clinical specimens. MATERIALS AND METHODS: HCT-8, LoVo, CT-26, and WiDr were the colon cancer cell lines used for this study. The clonogenic assay was performed to obtain the cell survival curves and surviving fractions at a dose of 2 Gy (SF2) as the standard technique for radiosensitivity. Also, the MTT assay was performed for each of the cell lines (in vitro). To simulate clinical specimens, the cell lines were inoculated into nude mice, removed when the tumors reached 1 cm in diameter, and chopped. Next, the tumors were subjected to the same process involved with the MTT assay in vitro. The inhibition rates (IR) of 10 Gy or 20 Gy of irradiation for in vitro and ex vivo were calculated based on the optical density of the MTT assay, respectively. RESULTS: According to SF2 and the cell survival curve, the HCT-8 and WiDr cell lines were more resistant to radiation than LoVo and CT-26 (p<0.05). The IR was measured by in vitro. The MTT assay IR was 17.3%, 21%, 30% and 56.5% for the WiDr, HCT-8, LoVo and CT-26 cell lines, respectively. In addition, the IR measured ex vivo by the MTT assay was 23.5%, 26%, 38% and 53% in the HCT-8, WiDr, LoVo and CT-26 tumors, respectively. CONCLUSION: The radiosensitivity measured by the MTT assay was correlated with the measures obtained from the clonogenic assay. This result highlights the possibility that the MTT assay could be used in clinical specimens for individual radiosensitivity assays.

12.
Korean Journal of Medical Physics ; : 87-92, 2007.
Artigo em Coreano | WPRIM | ID: wpr-107965

RESUMO

A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were performed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were 1.02E9 n/cm2 s and 6.07E8 n/cm2 s at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water. The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water. Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux. Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.


Assuntos
Nêutrons Rápidos , Terapia por Captura de Nêutron , Nêutrons , Eficiência Biológica Relativa , Água
13.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 268-277, 2007.
Artigo em Inglês | WPRIM | ID: wpr-159789

RESUMO

PURPOSE: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. MATERIALS AND METHODS: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. RESULTS: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the 30~50 mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. CONCLUSION: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.


Assuntos
Polietileno , Radiocirurgia , Amplitude de Movimento Articular , Respiração
14.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 11-20, 2006.
Artigo em Inglês | WPRIM | ID: wpr-16169

RESUMO

PURPOSE: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. MATERIALS AND METHODS: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status 80 cc (p-value80 cc showed better survival rate. CONCLUSION: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.


Assuntos
Humanos , Tratamento Farmacológico , Seguimentos , Expectativa de Vida , Análise Multivariada , Metástase Neoplásica , Neoplasias Pancreáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Qualidade de Vida , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
15.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 234-236, 2004.
Artigo em Coreano | WPRIM | ID: wpr-177345

RESUMO

No abstract available.


Assuntos
Radioterapia (Especialidade)
16.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 64-68, 2004.
Artigo em Coreano | WPRIM | ID: wpr-55467

RESUMO

PURPOSE: To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. MATERIALS AND METHODS: The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom in order to capture the visible light from the scintillation screen. To observe the dose distribution in real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the intensity modulated radiation therapy (IMRT). RESULTS: The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. CONCLUSIONS: Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.


Assuntos
Estudos de Viabilidade , Luz , Água
17.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 381-390, 2002.
Artigo em Coreano | WPRIM | ID: wpr-149289

RESUMO

PURPOSE: To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. MATERIALS AND METHODS: Currently, the most widely used dosimetry protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual C++ language for their ease of use in a Windows environment according to the recommendation of each protocols. RESULTS: The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. CONCLUSION: Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.


Assuntos
Calibragem , Água
18.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 66-73, 2001.
Artigo em Coreano | WPRIM | ID: wpr-76512

RESUMO

PURPOSE: For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. METHOD AND MATERIALS: For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, EIC-1 ion chambers manufactured by A-150 plastic and used IC-17M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was 5 cc per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. RESULTS: The absorbed dose of fast neutron beams was 6.47x10-3 cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was 65.2+/-0.9% at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, D20/D10, of the total dose was 0.718. CONCLUSION: Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.


Assuntos
Argônio , Bismuto , Terapia por Captura de Nêutron de Boro , Boro , Ciclotrons , Fontes de Energia Elétrica , Nêutrons Rápidos , Esperança , Coreia (Geográfico) , Magnésio , Nêutrons , Reatores Nucleares , Parafina , Plásticos , Água
19.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 369-380, 2001.
Artigo em Coreano | WPRIM | ID: wpr-16896

RESUMO

PURPOSE: By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. MATERIALS AND METHODS: The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internet Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. RESULTS: This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. CONCLUSION: We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.


Assuntos
Braquiterapia , Internet , Radioterapia (Especialidade) , Radioisótopos , Gestão da Segurança , Navegador
20.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 172-178, 1999.
Artigo em Coreano | WPRIM | ID: wpr-18878

RESUMO

PURPOSE: To measure the basic structural characteristics of radiation oncology facilities in Korea during 1997 and to compare personnel, equipments and patient loads between Korea and developed countries. METHOD AND MATERIALS: Mail serveys were conducted in 1998 and data on treatment machines, personnel and performed new patients were collected. Responses were obtained from the 100 percent of facilities. The consensus data of the whole contry were summarized using Microsoft Excel program. RESULTS: In Korea during 1997, 42 facilities delivered megavoltage radiation theraphy with 71 treatment machines, 100 radiation oncologists, 26 medical physicist, 205 technologists and 19,773 new patients. Eighty nine percent of facilities in Korea had linear accelators at least 6 MeV maxium photon energy. Ninety five percent of facilities had simulators while five percent of facilities had no simulator. Ninety one percent of facilities had computer planning systems and eighty three percent of facilities reported that they had a written quality assurace program. Thirty six percent of facilities had only one radiation oncologist and thirty eight percent of facilities had no medical physicists. The median of the distribution of annual patients load of a facility, patients load per a machine, patients load per a radiation oncologist, patients load per a therapist and therapists per a machine in Korea were 348 patients per a year, 263 patients per a machine, 171 patients per a radiation oncologis, 81 patients per a therapist, and 3 therapists per a machine respectively. CONCLUSION: The whole scale of the radiation oncology departments in Korea was smaller than Japan and USA in population ratio regard. In case of hardware level like linear accelerators, simulators and computer planning systems, there was no big diffrences bewteen Korea and USA. The patients loads of radiation oncologists and therapists had no significient differences as compared with USA. However, it was desirable to consider the part time system in USA because there were a lot of hospitals which did not employ medical physicists.


Assuntos
Humanos , Consenso , Países Desenvolvidos , Japão , Coreia (Geográfico) , Aceleradores de Partículas , Serviços Postais , Radioterapia (Especialidade)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA